High Quality Leak Detection Tool Fixed Single Hydrogen Gas Detector
Product Details
| Customization: | Available |
|---|---|
| After-sales Service: | One Year |
| Warranty: | 1 Years |
Shipping
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Payment Guarantee
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Manufacturer/Factory & Trading Company
Secured Trading Service
Diamond Member Since 2023
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
OEM Services
Product Certification
Flexible Customization
Self-branded
The supplier provides OEM services for popular brands
The supplier's products already have relevant certification qualifications, including:
RoHS
FCC
CE
SIL
IP67
RoHS
FCC
CE
SIL
IP67
The supplier provides Flexible customization services for your Personalized requirements
The supplier has 2 Self-brands, check the Audit Report for more information
Sign In to see all verified strength labels (28)
Find Similar Products
Basic Info.
- Model NO.
- NKYF-GZ+H2
- Brand
- Nkyf
- Customized
- Customized
- Portable
- Non Portable
- Certification
- FCC, CE, RoHS
- Type
- Fixed Gas Detector
- Product Name
- Fixed Gas Detector
- Output Signal
- RS485
- Measure Range
- 0-40000ppm
- Working Voltage
- DC 24V
- Explosion Proof Level
- Ex Ia Iic T6 Gaproduct
- Production Date
- June, 2024
- Transport Package
- Packaging & Deliverypackaging
- Specification
- Customized
- Trademark
- NKYF
- Origin
- Ningxia, China
- Production Capacity
- 10000 Set/Sets Per Year
Packaging & Delivery
- Package Size
- 35.00cm * 35.00cm * 25.00cm
- Package Gross Weight
- 5.000kg
Product Description

Gas sensor is a device that converts gas concentration information into weak electrical signals, and is the core of gas detector.
At the same time, the sensor is very sensitive and fragile. It needs to be carefully used and protected,
or it will cause performance degradation or damage. Therefore, the sensor is a worn out product.The following points should be noted during use:
1.The operating temperature of most electrochemical sensors is -20ºC ~ +50ºC, for infrared sensors is -40ºC ~ +70ºC, and the operating humidity is 15-95% RH(no condensation).Special sensor environment depends on specific model.
2.Ensure that the gas flowing into the sensor gas chamber does not contain impurities or stains, such as moisture and oil stains, which are easily attached to the sensor surface and cause sensor failure or damage.
3. The sensor is recommended to be calibrated every 3 months, depending on the field environment, such as whether there is often a large amount or a small amount of target detection gas in the field environment.
4. Electrochemical sensors have a service life about 2 years, and infrared sensors have a service life about 3 years. Special sensors depend on the specific model and field environment, whether the field environment temperature is too high or too low.
5. The sensor shall not be unplugged with electricity and shall not impact and fall;Its warranty terms are subject to the standards of sensor manufacturers, artificial damage or improper use, no warranty.
Note :
Please purchase and replace the sensor from our company. If the sensor is not approved by our company, the function and performance of the instrument may not meet the requirements of the design, or even the sensor or machine may be damaged.
Our company shall not be responsible for any loss caused thereby.

| Name | Descripition |
| Product name : | Fixed gas detector |
| Detection principle : | Capacity combustion; infrared detect ;eletrochemical ;PID; heat conductance; |
| Display mode : | LCD screen display ; |
| Display unit : | %VOL, %LEL, ppm, mg/m3 ; |
| Back light : | White ,yellow,red three color back light ,Normal, fault, alarm indication; |
| Alarm mode : | Sound and light alarm, relay output alarm |
| Precision : | ≤±3%FS; |
| Preheat time : | ≤90s;(according to different gases) |
Output signal : |
It can transmit up to 1200 meters (single core 1mm2 shielded cable) according to the actual environmental requirements of the site |
| 1 path 4~20mA current signal output | |
| 1path RS-485 signal output,standard ModBus RTU(optional function); | |
| 1path 200~1000Hzfrequency signal output(Output pin and sound and light alarm multiplexing, optional function); | |
| Can chose 0~5V or 0~10V output (optional function); | |
| Relay : | Two sets of OMRON relays;Passive contact capacity: 220VAC 0.5a or 24VDC 1A; |
| Material of body : | Shell :die-cast aluminium ; |
| Gas chamber :alumina carbide ; |
|
| Installation mode : | Wall mounted pipe integrated; |
| Working temperature : | -40ºC~+70ºC(combustible);-20ºC~+50ºC(toxic); |
| Working humidity : | 10%~95%RH(no condensation); |
| Working voltage : | 24VDC(normal operation voltage range:9~30VDC); |
| Power dissipation : | <2.5W(combustible gas );<1.5W(toxic gas ); |
| Working pressure : | 86~106KPa; |
| Dimension : | 180mm*140mm*92mm(L*W*H); |
| Weight : | About 1.6Kg ; |
| Explosion proof grade : | Exd IIC T6 Gb |
| Protection grade : | IP66; |
| Operation standard : | GB12358-2006,GB15322.1-2003,GB3836.1-2010, GB3836.2-2010,GB3836.4-2010; |
Product characteristics
fixed gas detection instrument (hereinafter referred to as the detector), through the sensor to collect the corresponding gas concentration, the target gas concentration is converted into the corresponding current or voltage signal and transmitted to the signal collection and processing circuit for filter amplifier and then to convert the AD module, eventually to CPU units for various operation, finally it is concluded that for the gas concentration, and the computing results for display and control of the corresponding unit module, for the various signal output and control.
This detector adopts the design scheme of instrument panel display interface and three-color backlight.Intuitive reading, failure and alarm indication;
The circuit board uses four layers of wiring, the craft is simple, use the flame-proof design; output signal can chose 4~20 mA RS485 0~5V 0~10V 200~1000Hz two sets of relay output;
It can be conveniently composed of safety protection system with DCS, PLC and ES90C series alarm host and central station software independently developed by our company.High detection sensitivity, fast reaction speed, strong anti-interference ability, stable and reliable performance, excellent signal processing algorithm, as the leading level products in China and abroad.
It can be widely used in metallurgical, petroleum, chemical, mining, coking, municipal, environmental protection, pharmaceutical, electric power, shipping, sewage treatment, laboratories, scientific research institutes and other places that need continuous testing of inflammable, explosive, toxic and harmful gases.
This detector adopts the design scheme of instrument panel display interface and three-color backlight.Intuitive reading, failure and alarm indication;
The circuit board uses four layers of wiring, the craft is simple, use the flame-proof design; output signal can chose 4~20 mA RS485 0~5V 0~10V 200~1000Hz two sets of relay output;
It can be conveniently composed of safety protection system with DCS, PLC and ES90C series alarm host and central station software independently developed by our company.High detection sensitivity, fast reaction speed, strong anti-interference ability, stable and reliable performance, excellent signal processing algorithm, as the leading level products in China and abroad.
It can be widely used in metallurgical, petroleum, chemical, mining, coking, municipal, environmental protection, pharmaceutical, electric power, shipping, sewage treatment, laboratories, scientific research institutes and other places that need continuous testing of inflammable, explosive, toxic and harmful gases.

|
Measured gas
|
Measuring range
|
Selectable range
|
Resolution
|
|
Combustible Ex
|
0-100%LEL
|
0-100%VOL
|
1%LEL/1%VOL
|
|
Oxygen O2
|
0-30%VOL
|
0-30%0-100%VOL
|
0.1%VOL
|
|
Hydrogen Sulfide H2S
|
0-100PPM
|
0-502001000PPM
|
0.1/1PPM
|
|
carbon monoxide CO
|
0-1000PPM
|
0-500/2000/5000PPM
|
0.1/1PPM
|
|
nitrogen dioxide NO2
|
0-20PPM
|
0-501000PPM
|
0.1/1PPM
|
|
natural gas
|
0-100%LEL
|
0-100%LEL
|
1%LEL
|
|
Nitrogen oxides
|
0-20PPM
|
0-501000PPM
|
0.1/1PPM
|
|
Methane CH4
|
0-100%LEL
|
0-100%LEL
|
1%LEL/1%VOL
|
|
carbon dioxide CO2
|
0-5000PPM
|
0-1%5%10%VOL
|
1PPM/0.01%VOL
|
|
Nitric oxide NO
|
0-250PPM
|
0-5001000PPM
|
1PPM
|
|
nitrogen N2
|
0-100%LEL
|
0-100%VOL
|
1%VOL
|
|
Alcohol
|
0-100%LEL
|
0-100%LEL
|
1%LEL/1%VOL
|
|
Sulphur dioxide SO2
|
0-20PPM
|
0-501000PPM
|
0.1/1PPM
|
|
Chlorine CL2
|
0-20PPM
|
0-10100PPM
|
0.1PPM
|
|
Dichlorosilane
|
0-20PPM
|
0-20100PPM
|
1PPM/0.1PPM
|
|
Ammonia NH3
|
0-100PPM
|
0-505001000PPM
|
0.1/1PPM
|
|
Silicon tetrachloride
|
0-20PPM
|
0-20100PPM
|
1PPM/0.1PPM
|
|
Hydrogen H2
|
0-100%LEL
|
0-1000PPM
|
1%LEL/1PPM
|
|
Phosphine PH3
|
0-20PPM
|
0-200-100PPM
|
0.01/0.1PPM
|
|
Hydrogen chloride HCl
|
0-20PPM
|
0-2050100PPM
|
0.01/0.1PPM
|
|
Acrylonitrile
|
0-100PPM
|
0-100PPM
|
1PPM/0.1PPM
|
|
TVOC
|
0-100PPM
|
0-100PPM
|
1PPM/0.1PPM
|
|
CLO2
|
0-50PPM
|
0-10100PPM
|
0.1PPM
|
|
Hydrogen cyanide HCN
|
0-50PPM
|
0-100PPM
|
0.1/0.01PPM
|
|
Ethylene oxide ETO
|
0-10PPM
|
0-100PPM
|
1PPM/0.1PPM
|
|
Ozone O3
|
0-10PPM
|
0-20100PPM
|
0.011PPM/0.1PPM
|
|
Formaldehyde CH2O
|
0-20PPM
|
0-50100PPM
|
1/0.1PPM
|
|
Fluorine gas F2
|
0-10PPM
|
0-110PPM
|
1PPM/0.1PPM
|
|
Hydrogen fluoride HF
|
0-10PPM
|
0-11050100PPM
|
0.01/0.1PPM
|
|
Xylene, Toluene
|
0-20PPM
|
0-51050100PPM
|
0.01/0.1PPM
|
|
malodor
|
0-100PPM
|
0-100PPM
|
1PPM/0.1PPM
|
NOTICE:
1.Q:Can I have a sample order to test quality?
A: Yes, we re commend and welcome sample order to test and check before order.
2.Q: Do you offer guarantee for the products?
A: Yes, we offer 1 or 2 years guarantee for the products.
3. Q: If I order big quantity, Can I have a cheaper price?
A: We will reduce the price according to the specific quantity and your requirements for the product.
4.Q: How does your I factory do regarding the quality control?
A: Quality is priority, Our factory has passed ISO 9001 with annual audit.
Established a procedure to check products at all stages of the manufacturing process-raw materials, in process materials. validated or tested materials, finished goods. etc.
Established a procedure to check products at all stages of the manufacturing process-raw materials, in process materials. validated or tested materials, finished goods. etc.
Send your message to this supplier
People who viewed this also viewed
Product Groups
Find Similar Products By Category
- Supplier Homepage
- Products
- Fixed gas detector
- Fixed Single Gas Detector
- High Quality Leak Detection Tool Fixed Single Hydrogen Gas Detector
Related Categories
Hot Searches
More