Product Name
Fixed Gas Detector
Explosion Proof Level
Ex Ia Iic T6 Gaproduct
Production Date
June, 2024
Transport Package
Packaging & Deliverypackaging
Product Description
How To Order?
1. Send Inquiry Or Contact Supplier!
2. In stock! Send out in 7 day, click "Start Order" and pay directly!
(Input quantity, choose your country, then you can see total price)
3. Please do write your Name, Address, Zip code and Phone number for delivery!
Products Description
Gas sensor is a device that converts gas concentration information into weak electrical signals, and is the core of gas detector. At the same time, the sensor is very sensitive and fragile. It needs to be carefully used and protected, or it will cause performance degradation or damage. Therefore, the sensor is a worn out product.The following points should be noted during use: - The operating temperature of most electrochemical sensors is -20ºC ~ +50ºC, for infrared sensors is -40ºC ~ +70ºC, and the operating humidity is 15-95% RH(no condensation).Special sensor environment depends on specific model.
- Ensure that the gas flowing into the sensor gas chamber does not contain impurities or stains, such as moisture and oil stains, which are easily attached to the sensor surface and cause sensor failure or damage.
3. The sensor is recommended to be calibrated every 3 months, depending on the field environment, such as whether there is often a large amount or a small amount of target detection gas in the field environment.
4. Electrochemical sensors have a service life about 2 years, and infrared sensors have a service life about 3 years. Special sensors depend on the specific model and field environment, whether the field environment temperature is too high or too low.
5. The sensor shall not be unplugged with electricity and shall not impact and fall;Its warranty terms are subject to the standards of sensor manufacturers, artificial damage or improper use, no warranty.
Note :
Please purchase and replace the sensor from our company. If the sensor is not approved by our company, the function and performance of the instrument may not meet the requirements of the design, or even the sensor or machine may be damaged. Our company shall not be responsible for any loss caused thereby. Product Parameters
Name | Descripition |
Product name : | Fixed gas detector |
Detection principle : | Capacity combustion; infrared detect ;eletrochemical ;PID; heat conductance; |
Display mode : | LCD screen display ; |
Display unit : | %VOL, %LEL, ppm, mg/m3 ; |
Back light : | White ,yellow,red three color back light ,Normal, fault, alarm indication; |
Alarm mode : | Sound and light alarm, relay output alarm |
Precision : | ≤±3%FS; |
Preheat time : | ≤90s;(according to different gases) |
Output signal : | It can transmit up to 1200 meters (single core 1mm2 shielded cable) according to the actual environmental requirements of the site |
1 path 4~20mA current signal output |
1path RS-485 signal output,standard ModBus RTU(optional function); |
1path 200~1000Hzfrequency signal output(Output pin and sound and light alarm multiplexing, optional function); |
Can chose 0~5V or 0~10V output (optional function); |
Relay : | Two sets of OMRON relays;Passive contact capacity: 220VAC 0.5a or 24VDC 1A; |
Material of body : | Shell :die-cast aluminium ; |
Gas chamber :alumina carbide ; |
Installation mode : | Wall mounted pipe integrated; |
Working temperature : | -40ºC~+70ºC(combustible);-20ºC~+50ºC(toxic); |
Working humidity : | 10%~95%RH(no condensation); |
Working voltage : | 24VDC(normal operation voltage range:9~30VDC); |
Power dissipation : | <2.5W(combustible gas );<1.5W(toxic gas ); |
Working pressure : | 86~106KPa; |
Dimension : | 180mm*140mm*92mm(L*W*H); |
Weight : | About 1.6Kg ; |
Explosion proof grade : | Exd IIC T6 Gb |
Protection grade : | IP66; |
Operation standard : | GB12358-2006,GB15322.1-2003,GB3836.1-2010, GB3836.2-2010,GB3836.4-2010; |
Product characteristics ES10B series fixed gas detection instrument (hereinafter referred to as the detector), through the sensor to collect the corresponding gas concentration, the target gas concentration is converted into the corresponding current or voltage signal and transmitted to the signal collection and processing circuit for filter amplifier and then to convert the AD module, eventually to CPU units for various operation, finally it is concluded that for the gas concentration, and the computing results for display and control of the corresponding unit module, for the various signal output and control.
This detector adopts the design scheme of instrument panel display interface and three-color backlight.Intuitive reading, failure and alarm indication; The circuit board uses four layers of wiring, the craft is simple, use the flame-proof design; output signal can chose 4~20 mA RS-485 0~5V 0~10V 200~1000Hz two sets of relay output;It can be conveniently composed of safety protection system with DCS, PLC and ES90C series alarm host and central station software independently developed by our company.High detection sensitivity, fast reaction speed, strong anti-interference ability, stable and reliable performance, excellent signal processing algorithm, as the leading level products in China and abroad.
It can be widely used in metallurgical, petroleum, chemical, mining, coking, municipal, environmental protection, pharmaceutical, electric power, shipping, sewage treatment, laboratories, scientific research institutes and other places that need continuous testing of inflammable, explosive, toxic and harmful gases.
Detailed Images
Click here to ask us for any detailed information about gas detectors!
Multi-gases Choices
NOTICE:
NKYF specializes in the production of various types of gas detectors.
If you are not sure which product to choose and what scenario is suitable for use, please feel free to contact us for free professional advice
Except belowing normal gases, other gases and measuring ranges are all support customized, please click to contact us for more details
Measured gas | Measuring range | Selectable range | Resolution |
Combustible Ex | 0-100%LEL | 0-100%VOL | 1%LEL/1%VOL |
Oxygen O2 | 0-30%VOL | 0-30%0-100%VOL | 0.1%VOL |
Hydrogen Sulfide H2S | 0-100PPM | 0-502001000PPM | 0.1/1PPM |
carbon monoxide CO | 0-1000PPM | 0-500/2000/5000PPM | 0.1/1PPM |
nitrogen dioxide NO2 | 0-20PPM | 0-501000PPM | 0.1/1PPM |
natural gas | 0-100%LEL | 0-100%LEL | 1%LEL |
Nitrogen oxides | 0-20PPM | 0-501000PPM | 0.1/1PPM |
Methane CH4 | 0-100%LEL | 0-100%LEL | 1%LEL/1%VOL |
carbon dioxide CO2 | 0-5000PPM | 0-1%5%10%VOL | 1PPM/0.01%VOL |
Nitric oxide NO | 0-250PPM | 0-5001000PPM | 1PPM |
nitrogen N2 | 0-100%LEL | 0-100%VOL | 1%VOL |
Alcohol | 0-100%LEL | 0-100%LEL | 1%LEL/1%VOL |
Sulphur dioxide SO2 | 0-20PPM | 0-501000PPM | 0.1/1PPM |
Chlorine CL2 | 0-20PPM | 0-10100PPM | 0.1PPM |
Dichlorosilane | 0-20PPM | 0-20100PPM | 1PPM/0.1PPM |
Ammonia NH3 | 0-100PPM | 0-505001000PPM | 0.1/1PPM |
Silicon tetrachloride | 0-20PPM | 0-20100PPM | 1PPM/0.1PPM |
Hydrogen H2 | 0-100%LEL | 0-1000PPM | 1%LEL/1PPM |
Phosphine PH3 | 0-20PPM | 0-200-100PPM | 0.01/0.1PPM |
Hydrogen chloride HCl | 0-20PPM | 0-2050100PPM | 0.01/0.1PPM |
Acrylonitrile | 0-100PPM | 0-100PPM | 1PPM/0.1PPM |
TVOC | 0-100PPM | 0-100PPM | 1PPM/0.1PPM |
CLO2 | 0-50PPM | 0-10100PPM | 0.1PPM |
Hydrogen cyanide HCN | 0-50PPM | 0-100PPM | 0.1/0.01PPM |
Ethylene oxide ETO | 0-10PPM | 0-100PPM | 1PPM/0.1PPM |
Ozone O3 | 0-10PPM | 0-20100PPM | 0.011PPM/0.1PPM |
Formaldehyde CH2O | 0-20PPM | 0-50100PPM | 1/0.1PPM |
Fluorine gas F2 | 0-10PPM | 0-110PPM | 1PPM/0.1PPM |
Hydrogen fluoride HF | 0-10PPM | 0-11050100PPM | 0.01/0.1PPM |
Xylene, Toluene | 0-20PPM | 0-51050100PPM | 0.01/0.1PPM |
malodor | 0-100PPM | 0-100PPM | 1PPM/0.1PPM |
Company Profile
FAQ
1.Q:Can I have a sample order to test quality? A: Yes, we re commend and welcome sample order to test and check before order.
2.Q: Do you offer guarantee for the products?
A: Yes, we offer 1 or 2 years guarantee for the products.
3. Q: If I order big quantity, Can I have a cheaper price?
A: We will reduce the price according to the specific quantity and your requirements for the product.
4.Q: How does your I factory do regarding the quality control?
A: Quality is priority, Our factory has passed ISO 9001 with annual audit. Established a procedure to check products at all stages of the manufacturing process-raw materials, in process materials. validated or tested materials, finished goods. etc.
Address:
Yiyuan Road No. 6, Yinchuan, Ningxia, China
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics, Industrial Equipment & Components, Instruments & Meters
Management System Certification:
ISO 9001, ISO 14001
Company Introduction:
Ningxia Nuoke Yinfeng Intelligent And Technology Co., Ltd is located in Ningxia, China′s chemical industry base. We have 23 years of experience in the research and development, production, sales, service and foreign trade export of gas detection instruments. The company has an independent R&D base of about 1, 000 square meters, 15 professional engineers, 4 production lines and a large number of production and service employees. At the same time, we have passed many certifications such as C E, RoHS, S I L, F C C, IP 6 7, I S O 9 0 0 0 1, etc. Our company′s main products include portable and fixed gas detectors, gas alarm controllers, wireless gas detection detector, GDS system, DCS system, toxic and harmful gas detectors, flammable and explosive gas detectors, pump-type gas detectors, etc. Each product must be tested and calibrated before leaving the factory, and a factory inspection report is issued. Our professional technical personnel, qualified workers, advanced and strict quality management system provide stable products and services. Our products are widely used in environmental protection, petroleum, chemical industry, shipbuilding, electric power, papermaking, metallurgy, pharmaceuticals, water treatment, food processing, coal and many other fields. Our products are sold overseas, not only supporting retail, wholesale or agency cooperation models, but also providing O E M/O D M/O B M services.