Determine Cl2 Concentration Alarm System Electrolysis Type Cl2 Sensor

Product Details
Customization: Available
Type: Catalytic Combustion Gas Sensor
Conductivity Type: Surface Type
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 4 patents, you can check the Audit Report for more information
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (28)
  • Determine Cl2 Concentration Alarm System Electrolysis Type Cl2 Sensor
  • Determine Cl2 Concentration Alarm System Electrolysis Type Cl2 Sensor
  • Determine Cl2 Concentration Alarm System Electrolysis Type Cl2 Sensor
  • Determine Cl2 Concentration Alarm System Electrolysis Type Cl2 Sensor
  • Determine Cl2 Concentration Alarm System Electrolysis Type Cl2 Sensor
  • Determine Cl2 Concentration Alarm System Electrolysis Type Cl2 Sensor
Find Similar Products
  • Overview
  • Products Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
ME4-NO2
Output Signal Type
Analog Type
Production Process
Injection
Material
Metal
IP Rating
IP67
Sensitivity
High
Certification
RoHS
Customized
Customized
Description
Electrochemical Module
Theory
Electrochemical Principle
Sensitivity (Lsb/G)
(1.2±0.3)Ua/Ppm
Humidity Range
15%~99%Rh
Resolution
0.1ppm
Measuring Range
0~20ppm
Output
Linearity
Usage
Quantitative Measurement of Gases
Mounting Type
Professional Installation
MOQ
2PCS
Response Time (T90)
<30s
Brand
Gas Sensor Module
Life
2 Year
Stability (Per Month)
< 2%
Application
Gas Analyse
Transport Package
Bag+Carton
Specification
17.5*17.6*15.7
Trademark
nkyf
Origin
Gansu, China
Production Capacity
100000 Piece/Pieces Per Month

Packaging & Delivery

Package Size
10.00cm * 10.00cm * 10.00cm
Package Gross Weight
0.700kg

Product Description

 
 
Products Description
 
ME4-NO2 sensor is a constant potential electrolysis type NO2 sensor. NO2 and O2 undergo corresponding REDOX reaction on the working electrode and the opposite electrode and release charge to form current. The current generated is proportional to the concentration of NO2. The concentration of NO2 can be determined by testing the current size
 
Features
Low power consumption and high precision High sensitivity and wide linear range Excellent repeatability and stability
Applications: Widely suitable for industrial, underground and environmental protection nitrogen dioxide detection
project
parameter
Detection gas
NO2
range
0-20ppm
Maximum measurement limit
150ppm
sensitivity
1.2±0.3uA/ppm
resolution
0.1 parts per million
Response time (T90)
< 30s
bias
0mV
Load resistance (recommended)
10 Ω
repeatability
< 2% output value
Stability (per month)
< 2%
Output linearity
linearity
Zero drift (-20-40)
0.2ppm
Temperature range
-20 to 50
Humidity range
15 % ~ 90% RH without condensation
Pressure range
Standard atmospheric pressure ±10%
Determine Cl2 Concentration Alarm System Electrolysis Type Cl2 Sensor
Determine Cl2 Concentration Alarm System Electrolysis Type Cl2 Sensor
Company Profile
Ningxia Nuoke Yinfeng Intelligent Technology Co., Ltd.
Specializing in the development, production, sales and technical services of gas detection instruments
Gas detection: Oxygen, various flammable and explosive gases, various toxic and harmful gases, volatile organic compounds (VOC), etc.
Applications:Environmental protection, petroleum, chemical, shipbuilding, electric power, papermaking, metallurgy, pharmaceutical, water treatment, food processing, coal, building and other fields of gas detection
Determine Cl2 Concentration Alarm System Electrolysis Type Cl2 SensorDetermine Cl2 Concentration Alarm System Electrolysis Type Cl2 SensorDetermine Cl2 Concentration Alarm System Electrolysis Type Cl2 SensorDetermine Cl2 Concentration Alarm System Electrolysis Type Cl2 Sensor
 
FAQ
 
1.Q:Can I have a sample order to test quality?
A: Yes, we re commend and welcome sample order to test and check before order.

2. Q: Do you offer guarantee for the products?
A: Yes, we offer 1 or 2 years guarantee for the products.

3. Q: If I order big quantity, Can I have a cheaper price?
A: We will reduce the price according to the specific quantity and your requirements for the product.

4.Q: How does your I factory do regarding the quality control?
A: Quality is priority, Our factory has passed ISO 9001 with annual audit.

Established a procedure to check products at all stages of the manufacturing process-raw materials, in process materials.validated or tested materials, finished goods.etc.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now