Operating Temperature: -20ºC~50ºC
Usage: Quantitative Measurement of Gases
Description: Electrochemical Module
Theory: Electrochemical Principle
Sensitivity (Lsb/G): (1.8±0.3)Ua/Ppm
Humidity Range: 0%~99%Rh
Customization:
Manufacturer/Factory & Trading Company
Gold Member Since 2023

Suppliers with verified business licenses

Ningxia, China
to see all verified strength labels (23)
  • Overview
  • Product Parameters
  • Products Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
ME3-ETO
Pressure Range
Standard Atmospheric Pressure
Mounting Type
Professional Installation
MOQ
1PCS
Brand
Gas Sensor Module
Measuring Range
0~20ppm
Output
Linearity
Bias
300mv
Stability (Per Month)
< 120%
Application
Gas Analyse
Transport Package
Bag+Carton
Origin
Henan, China
Production Capacity
100000 Piece/Pieces Per Month

Product Description

ME3-ETO constant potential electrolytic electrochemical ethylene oxide gas senso
 
Product Parameters
project
parameter
Detection gas
Ethylene oxide (ETO)
range
0~20ppm
Maximum measurement limit
100ppm
sensitivity
(1.8±0.3) uA/ppm
resolution
0.1 parts per million
Response time (T90)
The 120 s or less
bias
300mV
Load resistance (recommended)
10 Ω
repeatability
< 2% output value
Stability (per month)
< 2%
Output linearity
linearity
Zero drift (-20 ~ +40)
4ppm
Service temperature range
-20 to +50
Humidity range
15%-90% RH does not condense
Service pressure range
Standard atmospheric pressure ±10%
Service life
2 years
Products Description
 
ME3-ETO electrochemical gas sensor is a constant potential electrolysis sensor. The corresponding REDOX reaction occurs between ethylene oxide and oxygen on the working electrode and the opposite electrode and the charge is released to form a current. The current generated is proportional to the concentration of ethylene oxide, and the concentration of ethylene oxide can be determined by testing the size of the current.
 
 
Features
 
Low power consumption and high precision High sensitivity and wide linear range Excellent repeatability and stability
 
 
Applications:
Widely suitable for the detection of ethylene oxide in petroleum and petrochemical, pharmaceutical production and environmental protection fields
Me4-Hn3 Sensor Is a Constant Potential Electrolytic Hn3 Sensor Used to Determine
Me4-Hn3 Sensor Is a Constant Potential Electrolytic Hn3 Sensor Used to Determine
Me4-Hn3 Sensor Is a Constant Potential Electrolytic Hn3 Sensor Used to Determine
Company Profile
Ningxia Nuoke Yinfeng Intelligent Technology Co., Ltd.
Specializing in the development, production, sales and technical services of gas detection instruments
Gas detection:
Oxygen, various flammable and explosive gases, various toxic and harmful gases, volatile organic compounds (VOC), etc.
Applications:
Environmental protection, petroleum, chemical, shipbuilding, electric power, papermaking, metallurgy, pharmaceutical, water treatment, food processing, coal, building and other fields of gas detection
Me4-Hn3 Sensor Is a Constant Potential Electrolytic Hn3 Sensor Used to Determine
Me4-Hn3 Sensor Is a Constant Potential Electrolytic Hn3 Sensor Used to Determine
Me4-Hn3 Sensor Is a Constant Potential Electrolytic Hn3 Sensor Used to Determine
Me4-Hn3 Sensor Is a Constant Potential Electrolytic Hn3 Sensor Used to Determine
Me4-Hn3 Sensor Is a Constant Potential Electrolytic Hn3 Sensor Used to Determine
Me4-Hn3 Sensor Is a Constant Potential Electrolytic Hn3 Sensor Used to Determine
Me4-Hn3 Sensor Is a Constant Potential Electrolytic Hn3 Sensor Used to Determine
Me4-Hn3 Sensor Is a Constant Potential Electrolytic Hn3 Sensor Used to Determine
FAQ
Me4-Hn3 Sensor Is a Constant Potential Electrolytic Hn3 Sensor Used to Determine
1.Q:Can I have a sample order to test quality? A: Yes, we re commend and welcome sample order to test and check before order. 2. Q: Do you offer guarantee for the products? A: Yes, we offer 1 or 2 years guarantee for the products. 3. Q: If I order big quantity, Can I have a cheaper price? A: We will reduce the price according to the specific quantity and your requirements for the product. 4.Q: How does your I factory do regarding the quality control? A: Quality is priority, Our factory has passed ISO 9001 with annual audit.Established a procedure to check products at all stages of the manufacturing process-raw materials, in process materials.validated or tested materials, finished goods.etc.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now