Customization: | Available |
---|---|
Warranty: | 1 Year |
Customized Support: | OEM, ODM |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
tracer gas: | Carbon dioxide (CO2); ethanol (C2H6O); acetone (C3H6O); nitrous oxide (N2O) | ||
measuring range: | CO2:0-5000PPM;C2H6O:0-100%LEL;C3H6O:0-100PPM;N2O:0-10000PPM | ||
resolution ratio: | CO2:1PPM;C2H6O:0.1%LEL;C3H6O:0.01PPM;N2O:1PPM | ||
Extended gas: | Support for 1-5 sensors, any combination of various types of gas sensors, please refer to the relevant sensor parameters | ||
Dust particles: |
Optional PM2.5 laser dust particle sensor (0.3um, 2.5um, 10um) | ||
humiture: | Temperature detection range: -40 ~ 120ºC, and humidity detection range: 0-100% RH | ||
detection mode: | Pump suction type, built-in strong suction pump, flow rate: 500 mL/min adjustable, can work in the micro-negative pressure environment | ||
Detection accuracy: | ≤±3% | linear error: | ≤±2% |
response time: | 30 seconds (T90) | zero drift: | ≤±2%( F.S) |
recovery time: | Admito 20 seconds | repetitivenes s: | ≤±2% |
Detection mode: | Real-time detection and timing detection can be set | ||
memory module: | Real-time storage and timing storage can be set; a single channel can store 30800 data groups to view historical data on the screen | ||
Print mode: | Optional micro printer to print data, can be set: printing cycle, automatic printing, manual printing | ||
explosion- proof sign: | Ex iaIIC T4 Ga | Shell material: |
ABS+PC |
levels of protection: |
IP66 | working temperature: |
-20~ 50ºC |
working power supply: | 4000mA rechargeable polymer battery | Working humidity: |
95% RH, and no condensation |
Size weight: |
220*85*55 mm(L×W×H) 0.5 Kg (instrument net weight) |
working pressure: |
-30Kpa ~ 100Kpa |
standard fitting: | One instrument box, instruction manual, qualification certificate, USB charger, data cable, calibration cover | ||
Optional accessories: |
microwriter PM2.5 laser dust particle sensor Other various types of sensors, can be customized Water Gas Filter |
||
operative norm: |
GB3836.1-2010 The Explosive Environment- -Part 1: General Requirements for Equipment GB3836.4-2010 Explosive Environment-Part 4: Equipment protected by an intrinsically safe "i" |