Customization: | Available |
---|---|
Usage: | Quantitative Measurement of Gases |
Description: | Electrochemical Module |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
performance
|
output
|
Output at 20.9%O2 (µA)
|
80 ~ 120
|
|
Reaction time
|
t90 time from 20.9% to 0%O2 (s)
|
< 15
|
|
Zero current
|
Output in N2 (µA)
|
< 2.5
|
|
linearity
|
The percentage of oxygen deviation at 10%O2
|
0.6
|
Life span
|
Output drift
|
Percentage change in output over 3 months
|
< 1
|
|
Working life
|
Output dropped to 20.9%O2 The number of months the original output was 85%
|
> 24
|
environment
|
Humidity sensitivity
|
Percentage change of oxygen: 0~95%RH, 40°C
|
< 0.7
|
|
CO2 sensitivity
|
Percentage change in oxygen reading /CO2 concentration at 5% CO2
|
0.1
|
|
Pressure sensitivity
|
Percentage change in output/percentage change in pressure at 20kPa
|
< 0.1
|
Key parameter
|
Temperature range
|
|
- 30 to 55
|
|
Pressure range
|
kPa
|
80 ~ 120
|
|
Humidity range
|
Percentage of sustained relative humidity (0-99% RH in the short term)
|
5 ~ 95
|
|
Storage life
|
3~20 storage months (need to be stored in sealed tank, open circuit)
|
6
|
|
Load resistance
|
Ω (recommended)
|
47-100
|
|
diameter
|
mm (including labels)
|
20
|
|
height
|
mm (including foam washer)
|
17.4
|
|
weight
|
g
|
< 16
|